Released: 2018-08-21 11:00 Sources of information:: State Administration for Market Regulation
市监特〔2018〕37号
Provinces、Autonomous regions、Quality and Technical Supervision Bureau of the Municipality directly under the Central Government (Market Supervision and Administration Department),All relevant units:
About the "Elevator Supervision and Inspection and Periodic Inspection Rules - Traction and Forced Drive Elevators" (TSG T7001-2009 including No. 2 Amendment Order,hereinafter referred to as the new version of the inspection regulations) Annex A in 8.7(2)items for elevator emergency rescue access related requirements,After research, the following implementation suggestions are proposed:
One、In accordance with the General Office of the General Administration of Quality Supervision, Inspection and Quarantine on the implementation<Rules for elevator supervision and inspection and periodic inspection>and other 6 safety technical specifications No. 2 amendment list of several issues of the notice (Quality Inspection Office Special Letter [2017] No. 868).,Elevators that are supervised and inspected according to the new version of the inspection regulations,The access to each service landing of the elevator shall comply with 8.7 in Annex A(2)item,Subsequent periodic inspections should also meet the above requirements。
Two、For the elevators that have passed the supervision and inspection before the implementation of the new version of the inspection regulations,or an elevator added to an existing building,Such as due to building structure and other reasons,It is difficult to rectify the requirements of item 8.7(2) in Annex A,The user unit shall take feasible measures,Ensure that rescuers can open the doors and windows leading to the elevator service landing by key or compulsory means,Arrive at the service floor where the rescue is carried out in a timely manner,And carry out emergency rescue drills in accordance with regulations。The rescue measures involve the interests of the relevant owners,The consent of the relevant owner should be obtained。The user unit shall provide materials that meet the above requirements,The inspection agency can determine that the item meets the requirements。
Three、The inspected elevator originally met the requirements of 8.7 (2) in Annex A of the new version of the inspection regulations,The access to the service landing is artificially sealed,It must be rectified to meet the requirements。
Problems encountered in the implementation process in various places,Please report to our bureau。
市场监管总局办公厅